BP 40A and BP 60A SET UP MENU
BEC work under 3LIPO(10cell NIMh/NiCd) 5LIPO or 18 cells NIMh/NiCd MAX with BEC disabled First, connect the motor and receiver to the speed controller Remove battery power from the speed controller. Turn on the transmitter. Move throttle stick on full power position,(UP Position) Reconnect battery power to the speed controller After 3sec you can hear (all sound is 3times) — CELL Type AND Number — — BRAKE — — — TIMING MODE — — — — PWMON you need programming menu, move the throttle stick to middle position. 1 CELL Type AND Number• — NiMh/Nicd AUTO0.8V/CELL*•— — 3LIPO 2.75V/CELL•— — — 4LIPO2.75V/CELL•— — — — 5LIPO2.75V/CELL*IF used 2LIPO you can use the option .(select the NiMh/Nicd AUTO) 2 BRAKE• •— NO• •— — SOFT• •— — — MID• •— — — HARD3 TIMING MODE• ••— 2 º• ••— — 7 º• ••— — — 15º• ••— — — — 30º4 PWM• •••— 8KHZ• •••— — 16KHZ• •••— — — 32KHZIF the option is you need ,then move the throttle stick to UP position. The long BEEP is save the option. and the system will go to the programming menu. You can setup other options. When all you need option is setup OK, push the throttle stick to down position, after 1sec the system were save all option, you can start the motor now!! |